Publication related to RSI or an RSI staff member
High-performance liquid chromatography method for determination of N-glucuronidation of 4-aminobiphenyl by mouse, rat, and human liver microsomes.
A simple and sensitive method for determination of the N-glucuronidation activity of mouse, rat, and human liver microsomes toward the carcinogenic arylamine 4-aminobiphenyl (4-ABP) using high-performance liquid chromatography with ultraviolet detection has been developed. The method uses chemically synthesized 4-ABP-N-glucuronide (4-ABP-G) as a standard for method validation. Validation was done with respect to specificity, linearity, precision, accuracy, and lower limits of detection. The method was specific since there were no interference peaks from the reaction matrix. The calibration curve for 4-ABP-G was linear from 50 to 5000 pmol/200 microl with R2=0.999. The newly developed method has good precision and accuracy. The intra- and interday precisions were less than 5 and 10%, respectively, and the highest values for intra- and interday accuracies were -4.6 and -12%, respectively. The lower limit of detection was 10 pmol/200 microl. The developed method was used to determine the glucuronidation activity of mouse, rat, and human liver microsomes. Human liver microsomes were the most active in 4-ABP glucuronidation (344.1 pmol/min/mg) followed by rats (30.6 pmol/min/mg) and then mice (12.3 pmol/min/mg). Human UGT1A4 supersomes were much more active than UGT1A9 (184.4 mol/min/mg versus 25.2 mol/min/mg). These results are consistent with those of earlier studies that used the radioactive [C14]UDPGA.
Authors
- Al-Zoughool, Mustafa, Al-Zoughool M, Department of Environmental Health, University of Cincinnati College of Medicine, Cincinnati, OH 45267-0056, USA. alzougmh@email.uc.edu
- Talaska, Glenn, Talaska G,
A simple and sensitive method for determination of the N-glucuronidation activity of mouse, rat, and human liver microsomes toward the carcinogenic arylamine 4-aminobiphenyl (4-ABP) using high-performance liquid chromatography with ultraviolet detection has been developed. The method uses chemically synthesized 4-ABP-N-glucuronide (4-ABP-G) as a standard for method validation. Validation was done with respect to specificity, linearity, precision, accuracy, and lower limits of detection. The method was specific since there were no interference peaks from the reaction matrix. The calibration curve for 4-ABP-G was linear from 50 to 5000 pmol/200 microl with R2=0.999. The newly developed method has good precision and accuracy. The intra- and interday precisions were less than 5 and 10%, respectively, and the highest values for intra- and interday accuracies were -4.6 and -12%, respectively. The lower limit of detection was 10 pmol/200 microl. The developed method was used to determine the glucuronidation activity of mouse, rat, and human liver microsomes. Human liver microsomes were the most active in 4-ABP glucuronidation (344.1 pmol/min/mg) followed by rats (30.6 pmol/min/mg) and then mice (12.3 pmol/min/mg). Human UGT1A4 supersomes were much more active than UGT1A9 (184.4 mol/min/mg versus 25.2 mol/min/mg). These results are consistent with those of earlier studies that used the radioactive [C14]UDPGA.